Here you’ll find the most commonly asked questions and their answers. If you don’t find what you are looking for here, you can look through the:

TcUnit

This can be accomplished by keeping the function block under test as an instance variable of the test suite rather than the test method. You can download an example here. In this example, the FB_ToBeTested is instantiated under the test suite (FB_ToBeTested_Test), and can thus be controlled over multiple cycles. Then all that’s necessary to do is to set the condition for when the assertion should be made in the test itself, which in the example is when the TestSuiteTimer has elapsed (TestSuiteTimer.Q).

Required TcUnit version: 1.0 or later

Category: TcUnit

Previous

Next

Add DISABLED_ in front of the test name, for example:

TEST('DISABLED_ThisTestWillBeIgnored');

AssertEquals(Expected := a,
             Actual := b,
             Message := 'A does not equal B');

TEST_FINISHED();

Required TcUnit version: 1.0 or later

Category: TcUnit

Previous

Next

In a number of scenarios, TwinCAT won’t let you write directly to certain variables:

  • Due to access restrictions (e.g. a variable in a FB’s VAR)
  • The variable being set as I/O (i.e. AT %I* or AT %Q*)

Writing to these variables wouldn’t make sense and should be prevented in the normal PLC code, so having special privileges during testing is a must.
To support these cases, TcUnit provides helper functions like WRITE_PROTECTED_BOOL, WRITE_PROTECTED_INT (and so forth) for setting these type of variables. For an example of how to use these, let’s assume you have a test:

METHOD PRIVATE TestCommsOkChannelsLow
VAR
    EL1008 : FB_Beckhoff_EL1008;
END_VAR

Where the FB_Beckhoff_EL1008 holds a variable:

iChannelInput AT %I* : ARRAY[1..8] OF BOOL;

Now you might want to write a value to the first channel of the iChannelInput like:

TcUnit.WRITE_PROTECTED_BOOL(Ptr := ADR(EL1008.iChannelInput[1]),
                            Value := FALSE);

Whereas afterwards you can make an assertion as usual:

AssertFalse(Condition := EL1008.ChannelInput[1],
            Message := 'Channel is not false');

Required TcUnit version: 1.0 or later

Category: TcUnit

Previous

Next

You can accomplish this by the Hide reference option for referenced libraries. This option lets you hide TcUnit from your other projects.
Let’s assume you’ve developed a library MyLibrary, which has tests written in TcUnit. You make a PLC project MyProject, which references MyLibrary.

If you use Hide reference on TcUnit in MyLibrary, then TcUnit won’t show up in the imports list of MyProject. You can find it in the Properties tab:

Category: TcUnit

Previous

Next

I want to do an assertion on two variables both declared with the BIT-datatype, but I have noticed that a AssertEquals_BIT does not exist. What do I do?

The reason a AssertEquals_BIT does not exist is that TwinCAT does not allow a BIT-datatype as a variable input. If you have data declared with the BIT-type, the easiest way to do an assertion on these is to do a BIT_TO_BOOL conversion and use the AssertEquals_BOOL.

TEST('Testing_of_BIT_Type');

AssertEquals_BOOL(Expected := BIT_TO_BOOL(VariableDeclaredAsBit_A),
                  Actual := BIT_TO_BOOL(VariableDeclaredAsBit_B),
                  Message := 'The variables differ');

TEST_FINISHED();

Required TcUnit version: 1.0 or later

Category: TcUnit

Previous

Next

When TcUnit is running it allocates memory in the PLC to store the test results. The maximum number of tests for every test suite has been set to 100, which however is a configuration parameter for TcUnit and can be changed. Parameters for TcUnit (and in fact any library references) are stored in your project, which means that this change will be persistent for your project/library. To change this max amount, to say for instance 200 tests per test suite, go to the library references and select TcUnit, then go to GVLsGVL_Param_TcUnitMaxNumberOfTestsForEachTestSuite.

Required TcUnit version: 1.0 or later

Category: TcUnit

Previous

Next

Yes. By default TcUnit runs all the test suites and tests in parallel, in other words all test suites and tests are run at the same time. Sometimes it is however desirable to run either the test suites or tests (or both) in a sequence, for example if you get exceed overruns while running tests. Since TcUnit 1.2 (not yet released) it’s possible to run test suites in sequence (one after another) and/or individual tests in order (one after another).

To execute test suites in a sequence, simply replace TcUnit.RUN() with TcUnit.RUN_IN_SEQUENCE() in your main body of the test program. This will execute the test suites in the order that they were declared. So for example if we have defined the following test suites and test program:

PROGRAM PRG_TEST
VAR 
    fbDiagnosticMessageDiagnosticCodeParser_Test : FB_DiagnosticMessageDiagnosticCodeParser_Test;
    fbDiagnosticMessageFlagsParser_Test : FB_DiagnosticMessageFlagsParser_Test;
    fbDiagnosticMessageParser_Test : FB_DiagnosticMessageParser_Test;
END_VAR

TcUnit.RUN_IN_SEQUENCE();

This will first execute all tests defined in fbDiagnosticMessageDiagnosticCodeParser_Test, once all tests are finished in that function block, TcUnit will execute all tests in fbDiagnosticMessageFlagsParser_Test, and when that is done it will execute all tests in fbDiagnosticMessageParser_Test.

It’s also possible to execute individual tests in order by simply replacing TEST('TestName') with TEST_ORDERED('TestName'). This will execute the tests in the order that the TEST_ORDERED() is called for the various tests. TEST_ORDERED() returns a boolean to indicate whether the TcUnit framework will run the test, so in order to only execute the code when it’s time for that particular test, it makes sense to check if TEST_ORDERED() returns true, and only then do the execution of the function blocks and assertions, for example like this:

METHOD PRIVATE TestWithTimestampZeroTimeExpectCurrentTime
VAR
   ... (variable declaration used for the test)
END_VAR

IF TEST_ORDERED('TestWithTimestampZeroTimeExpectCurrentTime') THEN
    fbFunctionBlockUnderTest(Parameters);

    AssertEquals(Expected := 'SomeValue',
                 Actual := fbFunctionBlockUnderTest.OutVariable,
                 Message := 'Test failed');

    TEST_FINISHED();
END_IF

As usual, the TEST_FINISHED() will indicate that this test is finished, and the framework will go to the next test. Note that you don’t need to create any state machine for calling the different TEST_ORDERED() tests. You can (and must!) call all TEST_ORDERED() at the same time. The framework will make sure to only care about the assertions of the test that is currently running.

This means the following combinations can be used:

  • RUN() with all tests as TEST() – means all tests suites and tests will run in parallel, this is the default behaviour in all previous versions of TcUnit
  • RUN_IN_SEQUENCE() with all tests as TEST() – means all test suites will run in sequence, but the tests in every test suite will run in parallel
  • RUN() with all tests as TEST_ORDERED() – means all test suites will run in parallel, but the tests in every test suite will run in sequence
  • RUN_IN_SEQUENCE() with all tests as TEST_ORDERED() – means all test suites will run in sequence, as will every test

For maximum flexibility, these combinations are allowed as well for special occasions:

  • TcUnit.RUN() with mixed tests of TEST() and TEST_ORDERED()– means all tests suites will run in parallel, with tests marked as TEST() run in parallel with tests that are marked with TEST_ORDERED() that run in sequence (relative to each other)
  • TcUnit.RUN_IN_SEQUENCE() with mixed tests of TEST() and TEST_ORDERED() – means all test suites will run in sequence, with tests marked as TEST() run in parallel with tests that are marked with TEST_ORDERED() that run in sequence (relative to each other)

If you run tests with both TEST() and TEST_ORDERED(), all tests defined with TEST() will run in parallel with the tests that are TEST_ORDERED().

Note that you can’t execute test-suites with both TcUnit.RUN() and TcUnit.RUN_IN_SEQUENCE() at the same time (which wouldn’t make any sense).

For a couple of TwinCAT projects that shows how to run both test suites in a sequence and individual tests in order, click here.

Required TcUnit version: 1.2 or later (not yet released)

Category: TcUnit

Previous

Next

TcUnit-Runner

No, Jenkins is just used as one example of an automation server. Any automation server of your choice should work fine, as long as it can execute the LaunchTcUnit.bat windows batch script or the TcUnit-Runner.exe windows executable, and it can handle standard  xUnit/JUnit XML format it should work just fine.

Category: TcUnit-Runner

Previous

Next

Check the console output in Jenkins if it provides any information. Also, try to build the project manually (by opening Visual Studio) on the build server and check if builds correctly.

Category: TcUnit-Runner

Previous

Next

Yes, this is possible with the limitation that it is not possible to run TwinCAT on a Windows/shared core but instead it is required that TwinCAT (and more specifically the unit-tests) are to be run on an isolated core in the virtual machine. Go here to read more on the subject.

Category: TcUnit-Runner

Previous

Next